Data Centre BIM Modelling Services Ireland
Optimar Precon provides data centre BIM modelling services in Ireland for contractors and design teams: coordinated Revit models of the data halls, the on-site power plant and the battery storage compound that Irish connection rules now require.
Models are delivered to I.S. EN ISO 19650 and organised by energisation phase, so each stage of the campus can be coordinated, built and handed over in turn.
Send Your BIM Brief
Tell us about the campus layout, power plant scope and exchange dates, and we will propose a modelling team and schedule.
Group-wide figures across all Optimar Precon services.
Modelling the Data Centre and Its Power Plant Together
On an Irish data centre, the generation plant and storage compound sit beside the data halls. Coordinating them in one federated model prevents clashes at the boundaries.
| Campus zone | Modelling focus | Coordination risk we check |
|---|---|---|
| Data halls | Cooling, power distribution and containment | Busway, cable tray and pipework congestion |
| Electrical rooms | HV and LV switchgear, UPS and transformers | Working clearances and equipment replacement routes |
| Generation plant | Gas engines or turbines, exhaust stacks, fuel systems | Stack heights, access and maintenance zones |
| Battery storage compound | BESS containers, inverters, transformers | Separation distances and fire access routes |
| Connection corridors | Gas pipeline, export cables and grid substation | Crossings between gas, power and drainage routes |
| Renewable interfaces | Solar arrays or private-wire connections | Cable routes and point-of-connection equipment |
Phased Models for Phased Energisation
Irish data centres are often energised in steps as generation comes online. The model is set up so every phase can be coordinated and recorded on its own.
Phase-Based Model Structure
Models split by phase, so each energisation stage can be issued, coordinated and approved separately.
Capped Connections
Future connection points, valves and spare ways modelled so later phases tie in cleanly.
Future Tie-In Zones
Space reserved for later plant, cabling and pipework, protected in the coordination model.
As-Built by Phase
Each completed phase recorded as built before the next phase starts.
Data Centre Models at Each Irish Project Stage
| Stage | Model deliverable | Purpose |
|---|---|---|
| Planning | Massing models, site layouts and visualisations | Supports planning drawings and environmental assessment inputs |
| Detailed design | Coordinated discipline models | Resolves clashes between data halls, plant and connection routes |
| Construction | Fabrication and installation models | Supports prefabricated plant, risers and pipework |
| Handover | As-built models with asset data | Gives the operator verified records for each phase |
Ireland adopts ISO 19650 as I.S. EN ISO 19650 through NSAI. Optimar Precon is certified to ISO 19650 for BIM information management and to ISO/IEC 27001 for information security.
Ireland Data Centre BIM Deliverables
Federated Campus Model
Data halls, power plant, BESS and corridors in one coordination model.
Revit M&E Models
Electrical, mechanical and fire protection models for each building.
Power Plant Models
Generation sets, stacks, fuel systems and BESS compound layouts.
Clash Reports
Navisworks clash tests with issues tracked to closure.
Planning Support Models
Massing and layout models for planning submissions.
Phased As-Builts
Verified as-built models and asset data for each energisation phase.
Related services: Ireland data centre preconstruction, Ireland data centre estimating, preconstruction services Ireland, data centre MEP clash detection case study, US data centre BIM modelling.
Coordinating a Data Centre With Its Own Power Plant?
Send the current models and site layout, and we will scope the coordination for the data halls and plant together.
Ireland Data Centre BIM Modelling: FAQs
Why model the power plant with the data centre in Ireland?
Most new Irish data centres need on-site generation or storage, which sits beside the data halls. Modelling both in one federated model catches clashes between plant, cable routes, gas pipework and access roads before construction.
Can you model battery storage compounds?
Yes. BESS containers, inverters, transformers and cable routes are modelled with separation distances and fire access routes, so the compound layout can be checked against the rest of the campus.
How do you handle phased energisation in the model?
Models are split by phase, with capped connections and reserved tie-in zones for later stages. Each phase is coordinated, issued and recorded as built on its own.
Can BIM models support Irish planning applications?
Yes. Massing models, site layouts and visualisations from the BIM model can support planning drawings and environmental assessment inputs, and are carried forward into detailed design.
Is your BIM delivery aligned with I.S. EN ISO 19650?
Yes. Ireland adopts ISO 19650 as I.S. EN ISO 19650, and Optimar Precon is certified to ISO 19650 for BIM information management.
Which software and file formats do you model in?
Models are built in Revit and coordinated in Navisworks, with exchanges through Autodesk Construction Cloud or the client’s common data environment and IFC exports for other platforms.
Coordinate the Whole Irish Campus
Data halls, power plant and grid connections, modelled and coordinated together.