USA | Data Center Cooling Estimating

Data Center Mechanical & Liquid Cooling Estimating

Optimar Precon provides data center mechanical estimating for US mechanical contractors and general contractors. We take off and price the full cooling system, from chillers, cooling towers and chilled water piping to CRAH units, CDUs and direct-to-chip liquid cooling loops.

Each estimate follows the designed cooling architecture, separates vendor equipment from piping and labor, and draws a clear line between facility-side and IT-side liquid cooling scope.

Chiller Plant & CHW Piping
CDU & Direct-to-Chip Scope
CSI Division 23 BOQ
N+1 & Dual-Path Cooling
Request a Mechanical Estimate →
Data Center Cooling Bids

Send Your Mechanical Package

Share your mechanical drawings, equipment schedules, project location and bid deadline. We will confirm the scope, fee and delivery date with your quotation.

29+Years of Group Experience
3,270+Projects Completed Across Services
98%Client Retention
7+Global Delivery Centers

Group-wide figures across all Optimar Precon services.

ISO9001
Quality ManagementDocumented estimate QA and review
ISO27001
Information SecurityControlled access to bid drawings
ISO27701
Privacy InformationManaged handling of project data
ISO19650
BIM InformationStructured model and data exchange
Mechanical Scope We Take Off and Price

Eight Data Center Cooling Packages, Estimated Separately

Cooling is usually the second-largest package on a data center bid. Pricing each part of the system on its own keeps chiller and CDU quotes visible and makes piping labor easy to check.

01

Chiller Plant

Air-cooled or water-cooled chillers, plant pumps, headers and plant controls.

23 64 · 23 21
02

Heat Rejection

Cooling towers, dry coolers, condenser water piping and basin heaters.

23 65 · 23 21
03

Chilled Water Distribution

Supply and return piping by size and material, valves, supports, expansion and air separation.

23 21 · 23 05
04

White Space Air Cooling

CRAH units, CRAC units, fan walls, in-row coolers and rear-door heat exchangers.

23 81 · per spec
05

Liquid Cooling (Facility Side)

CDUs, facility water connections, secondary loop piping, manifolds and leak detection.

23 21 · per spec
06

Support Space HVAC

Electrical room and UPS room cooling, battery room exhaust, offices and ductwork.

23 31 · 23 34
07

Insulation and Water Treatment

Piping and equipment insulation, chemical treatment, filtration and side-stream systems.

23 07 · 23 25
08

Controls and Monitoring

BMS and plant controls, sensors, control valves, points wiring and sequences support.

23 09
How the Estimate Is Built

We Estimate the Cooling System Loop by Loop

Data center cooling repeats the same equipment across halls and phases, and liquid-cooled halls add a second loop. Tracing each loop from heat rejection to rack prevents double counts at the handoffs between packages.

Simplified data center chilled water and liquid cooling loops Cooling towers reject heat from the chiller plant. The chilled water loop feeds CRAH units for air-cooled racks and CDUs for liquid-cooled racks. Each CDU feeds a technology cooling loop to direct-to-chip racks. Cooling Towers Chiller PlantChillers + Pumps Condenser water Chilled WaterSupply / Return CRAH / Fan Walls Air-Cooled Racks Supply air CDU Direct-to-ChipRacks TCS loop FWS AIR COOLING LIQUID COOLING CENTRAL PLANT PACKAGE
Simplified chilled water system with an air-cooled hall and a liquid-cooled hall. FWS = facility water system; TCS = technology cooling system.

1. Reconcile the Schedules

Chiller, CRAH and CDU schedules are matched to the flow diagram and plans, so capacities, quantities and redundant units agree before counting starts.

2. Count Equipment, Measure Piping

Equipment is counted by capacity and type. Piping is measured by size, material and joining method, with every valve, fitting and support captured.

3. Extend by Hall and Phase

One typical hall is built in detail, then extended across halls and phases, with air-cooled and liquid-cooled halls priced as separate modules.

Cooling Architectures

Which Cooling Design Are You Bidding?

The cooling architecture changes the equipment list, the piping and who installs what.

ArchitectureMain equipmentWhat drives the estimate
Water-cooled chilled waterWater-cooled chillers, cooling towers, CRAH unitsCondenser and chilled water piping, tower erection, water treatment
Air-cooled chilled waterAir-cooled chillers, often with free-cooling coilsRoof or yard chiller setting, rigging, glycol systems
DX / CRAC-basedCRAC units with remote condensersRefrigerant piping, condenser placement, unit count
Close-coupled airIn-row coolers, rear-door heat exchangersMany small connections at rack rows, branch piping and valves
Direct-to-chip liquidCDUs, secondary loop, rack manifoldsCDU count, TCS piping, flushing, cleanliness and scope boundary with IT
ImmersionImmersion tanks, CDUs or heat exchangersTank setting, facility water connections, fluid handling and owner scope
Takeoff Units and Cost Basis

How Each Mechanical Item Is Measured and Priced

Clear units make the estimate easy to check against equipment quotes and your own labor units.

ItemTakeoff unitWhat we captureTypical cost basis
ChillersEachTonnage, type, location, rigging pathVendor quote or OFCI install only
Cooling towers / dry coolersEach / cellCapacity, cells, field erection or packagedVendor quote + erection labor
PumpsEachFlow, head, motor size, VFDVendor quote + setting labor
CHW and CW pipingLF by sizeDiameter, material, welded or groovedMaterial + labor units
Valves and specialtiesEach by sizeIsolation, balancing, control and check valvesMaterial + labor units
InsulationLF by sizeThickness, jacket, fittingsMaterial + labor units
CRAH / fan walls / in-rowEachCapacity, connections, controlsVendor quote or OFCI install only
CDUs and TCS pipingEach / LFCDU capacity, manifolds, hoses, quick-connectsVendor quote + material and labor
Controls pointsEachSensors, actuators, points per deviceControls subcontract or labor units
Liquid Cooling and AI Data Centers

Liquid Cooling Estimates Start With the Scope Boundary

High-density AI halls move heat into water at the rack. The most common bid risk is not the piping itself but unclear ownership between the mechanical contractor, the CDU vendor and the owner’s IT team. We map that boundary before pricing.

ZoneTypical itemsUsually priced byWhat we confirm
Facility water system (FWS)Chilled or warm water piping from the plant to each CDUMechanical contractorPipe sizes, tie-in points, valves and isolation at each CDU
Coolant distribution units (CDUs)In-row or floor-mounted CDUs, pumps and heat exchangersMechanical contractor or owner (OFCI)Who supplies, who sets and who connects each CDU
Technology cooling system (TCS)Secondary loop piping, row manifolds, hoses, quick-connectsMechanical contractor, CDU vendor or integratorWhere contractor scope stops: at the manifold or at the rack
IT equipmentCold plates, server-level connections, racksOwner / IT integratorExclusions listed clearly in the scope log

Cleanliness and Flushing

Liquid cooling loops need tighter cleanliness than standard chilled water. We price flushing, filtration, passivation and fluid fill as separate line items.

Pipe Materials

TCS loops often specify stainless steel or approved polymers. Material and joining method change both cost and labor, so we price exactly what is specified.

Hybrid Halls

Most AI halls still need air cooling for residual heat. We estimate the air and liquid systems together so neither is missed or counted twice.

Redundancy and Cost Drivers

How Cooling Redundancy Changes the Mechanical Estimate

Mechanical redundancy shows up in equipment counts and, just as much, in piping layout and valving. We price the design shown, not a rule-of-thumb multiplier.

ApproachHow it worksWhat it adds to the estimate
N+1 equipmentOne spare chiller, pump, tower cell or CRAH in each group.Extra units with their piping connections, valves and controls.
Looped distributionChilled water mains run as a ring so any section can be isolated.Additional main piping, isolation valves and supports.
Dual-path (A/B) pipingTwo independent supply and return paths to critical equipment.A second set of mains and branches, plus more valves and insulation.
Concurrent maintainabilityAny component can be serviced without shutting down cooling.More isolation valves, bypasses and redundant connections.
Thermal storageChilled water tanks carry the load during a chiller restart.Storage tanks, foundations, piping connections and controls.

A Tier III or Tier IV target does not fix the mechanical bill of materials on its own. We price the redundancy shown on the drawings and flag any gaps against the stated resilience criteria.

Labor and Installation Drivers

What Moves Mechanical Labor Hours on a Data Center

Large-Bore Piping

Welded versus grooved joints, pipe size and elevation change labor units more than any other mechanical factor.

Chiller and Tower Rigging

Crane picks to roofs or yards, rigging plans and set sequences are priced as their own activities.

Prefabricated Pipe Racks and Skids

Off-site fabrication shifts labor from field installation to setting, connecting and testing modules.

Testing, Flushing and Fill

Hydrostatic testing, flushing, treatment and fill are priced per loop, with extra cleanliness steps for liquid cooling.

Phased Cooling Capacity

Halls brought online in phases add capped connections, future tie-ins and remobilization.

Owner-Furnished Equipment (OFCI)

Owners often buy chillers, CRAH units or CDUs directly. We split OFCI from CFCI so you price installation only where the owner supplies the equipment.

Mechanical Estimate Deliverables

A Division 23 Estimate Your Bid Team Can Check Line by Line

The mechanical BOQ follows CSI MasterFormat Division 23 sections, or maps to your company’s own cost codes.

SectionTitleTypical data center items
23 05Common Work Results for HVACSupports, hangers, meters, gauges, testing and balancing
23 07HVAC InsulationChilled water piping and equipment insulation
23 09Instrumentation and Control for HVACPlant controls, sensors, control valves, BMS integration
23 21Hydronic Piping and PumpsChilled, condenser and secondary loop piping, pumps
23 25HVAC Water TreatmentChemical treatment, filtration, side-stream systems
23 31HVAC Ducts and CasingsSupport space ductwork and plenums
23 64Packaged Water ChillersAir-cooled and water-cooled chillers
23 65Cooling TowersPackaged and field-erected cooling towers
23 81Decentralized Unitary HVAC EquipmentComputer-room air conditioners (CRAC units)
01Priced Mechanical BOQQuantities, units, material and labor by section, hall and phase.
02Equipment Schedule CheckChiller, CRAH and CDU schedules matched to plans, with gaps listed for RFI.
03Quote Leveling SheetChiller, tower and CDU quotes compared on inclusions, exclusions and lead items.
04Alternates and Scope LogWelded vs grooved, pipe material, OFCI/CFCI split, liquid cooling boundary.
What to Send

Drawings and Documents We Need

Send what you have; anything missing goes into the scope log as a qualification.

  • Mechanical plans and chilled water flow diagrams
  • Equipment schedules (chillers, towers, pumps, CRAH, CDUs)
  • Piping plans, sections and details
  • Division 23 specifications and addenda
  • Vendor quotes and OFCI equipment list
  • Liquid cooling responsibility matrix, if available
Estimating Tools

Mechanical Takeoff and Pricing Platforms

Our estimators work in the takeoff and estimating platforms below, or in the tools your bid team already uses.

Bluebeam Revu PlanSwift Trimble Estimating Microsoft Excel
Who We Support

Mechanical Estimating Support for US Data Center Bid Teams

Project-based estimates for a single bid, or dedicated offshore mechanical estimators for contractors with a steady data center pipeline.

Mechanical Contractors

Full Division 23 bid estimates, or overflow takeoff when your estimators are stretched across several data center bids.

General Contractors

Independent mechanical estimates to check subcontractor numbers, level bids and spot liquid cooling scope gaps.

Design-Build Teams

Budget and design-development estimates as the cooling design matures, with alternates for value engineering.

Who Leads Your Estimate

Shashin Gundal

Estimation Lead, Optimar Precon

Shashin leads Optimar Precon’s estimating team, which prepares mechanical and multi-trade packages for US contractor bids.

Drawing and Data Security

Your Mechanical Drawings Stay Protected

Data center cooling layouts reveal capacity and design details. Our information handling is certified to ISO/IEC 27001 and ISO/IEC 27701.

NDA signed before any drawings are shared
Named estimators with controlled file access
Information security managed under ISO/IEC 27001
Privacy information managed under ISO/IEC 27701

Bidding a Data Center Cooling Package?

Send the mechanical drawings, equipment schedules and bid deadline, and we will confirm scope, fee and delivery date for your estimate.

Send Your Mechanical Drawings →
Frequently Asked Questions

Data Center Mechanical and Liquid Cooling Estimating FAQs

What does data center mechanical estimating include?

It covers the full cooling system: chillers, cooling towers, pumps, chilled and condenser water piping, CRAH and CRAC units, liquid cooling CDUs and secondary loops, support space HVAC, insulation, water treatment and controls. Vendor equipment is kept separate from material and labor, and testing and owner-furnished equipment are listed.

How do you estimate liquid cooling for AI data centers?

We first map the scope boundary between the facility water system, the CDUs, the technology cooling system and the owner’s IT equipment. Then we count CDUs, measure facility and secondary loop piping by size and material, and price manifolds, hoses, flushing, filtration and fluid fill as separate items.

What is the difference between the FWS and TCS in liquid cooling?

The facility water system (FWS) carries chilled or warm water from the central plant to each CDU. The technology cooling system (TCS) is the secondary loop from the CDU to the racks and cold plates. The CDU separates the two, and each loop is usually priced by different parties.

How does cooling redundancy affect the mechanical estimate?

N+1 adds spare chillers, pumps, tower cells or CRAH units. Looped or dual-path piping adds a second set of mains, branches and isolation valves. Concurrent maintainability and thermal storage add bypasses, tanks and controls. We price the redundancy shown on the drawings.

How do you handle owner-furnished chillers, CRAH units or CDUs?

Data center owners often buy major cooling equipment directly. We split owner-furnished, contractor-installed (OFCI) items from contractor-furnished (CFCI) items, price installation only for OFCI equipment, and list receiving, rigging and setting responsibilities in the scope log.

Do mechanical estimates include testing, flushing and commissioning?

Yes, where it is in your scope. We price hydrostatic testing, flushing, chemical treatment and fill for each loop, plus contractor support for commissioning from factory witness testing (L1) through integrated systems testing (L5).

How much does outsourced data center mechanical estimating cost?

Project-based estimating starts from $20 per hour. The total depends on the number of halls, phases, cooling architecture, drawing quality and revisions. You receive a fixed quotation after a scope review, and dedicated mechanical estimators are priced as an ongoing monthly resource.

What drawings do you need to start a mechanical estimate?

Send the mechanical plans, chilled water flow diagrams, equipment schedules, piping plans and details, Division 23 specifications, addenda, vendor quotes and the OFCI equipment list. For liquid cooling, include any responsibility matrix showing where contractor scope ends.

Get a Data Center Cooling Estimate You Can Bid With

Share your mechanical package and deadline, and we will scope the takeoff, pricing and delivery date with you.